1. Basic concepts and functions of fire detection fans in power plants
The power plant fire detection fan is a type of power system safety equipment. It is mainly used to transport gas, inhale combustible gas, increase oxygen content, etc., to help firefighters detect, control and extinguish fires. Fire detection fans in power plants are usually installed in motor workshops, substations and other places to ensure the safe and stable operation of the power system.
2. Function and principle of fire detection fan in power plant
1. Transport gas
When a fire occurs, the power plant's fire detection fan can transport gas through circulation, discharge harmful gases and smoke from the fire site, increase the oxygen content at the site, and provide better rescue conditions for firefighters.
2. Inhalation of flammable gases
At the fire site, the power plant fire detection fan can reduce the spread of fire by inhaling flammable gases and provide strong support for controlling the fire source.
3. Detect fire
The power plant fire detection fan can also detect fires, control fire sources, and improve fire warning capabilities through intelligent sensors such as inductive sensors, thereby achieving all-round, full-time monitoring and control of power plant safety.
3. Advantages of fire detection fans in power plants
1.Quick response
The power plant fire detection fan has the advantage of rapid response. Once a fire is detected, it can be started and deliver gas in a short time.
2.Wide range of action
The power plant fire detection fan has a wide range of functions and can act on multiple locations at the same time, providing guarantee for better detection, control and extinguishing of fires.
3. Simple operation
The power plant fire detection fan is simple to use and easy to operate, and does not require skilled fire handling experience and skills.
No |
Rotating speed r/min |
Air volume m3/h |
Full pressure Pa |
Motor |
|
model |
Power(kw) |
||||
4 |
2900 |
824 |
3584 |
Y90L-2 |
2.2 |
970 |
3665 |
||||
1116 |
3647 |
||||
1264 |
3597 |
||||
1410 |
3507 |
Y100L-2 |
3 |
||
1558 |
3384 |
||||
1704 |
3253 |
||||
4.5 |
2900 |
1174 |
4603 |
Y112M-2 |
4 |
1397 |
4684 |
||||
1616 |
4672 |
||||
1839 |
4580 |
||||
2062 |
4447 |
||||
2281 |
4297 |
Y132S1-2 |
5.5 |
||
2504 |
4112 |
||||
5 |
2900 |
1610 |
5697 |
Y132S2-2 |
7.5 |
1932 |
5768 |
||||
2254 |
5740 |
||||
2576 |
5639 |
||||
2844 |
5517 |
||||
3166 |
5323 |
||||
3488 |
5080 |
Y160M1-2 |
11 |
||
5.6 |
2900 |
2262 |
7182 |
Y160M1-2 |
11 |
2714 |
7273 |
||||
3167 |
7236 |
||||
3619 |
7109 |
||||
3996 |
6954 |
Y160L-2 |
18.5 |
||
4448 |
6709 |
||||
4901 |
6400 |
||||
6.3 |
2900 |
3220 |
9149 |
Y160L-2 |
18.5 |
3865 |
9265 |
||||
4509 |
9219 |
||||
5153 |
9055 |
||||
5690 |
8857 |
Y200L1-2 |
30 |
||
6334 |
8543 |
||||
6978 |
8148 |
||||
7.1 |
2900 |
4610 |
11717 |
Y200L2-2 |
37 |
5532 |
11868 |
||||
6454 |
11807 |
||||
7376 |
11596 |
||||
8144 |
11340 |
Y250M-2 |
55 |
||
9066 |
10935 |
||||
9988 |
10426 |
||||
8 |
2900 |
6594 |
15034 |
Y280S-2 |
75 |
7913 |
15229 |
||||
9232 |
15151 |
||||
10550 |
14877 |
||||
11649 |
14546 |
||||
12968 |
14021 |
Y315S-2 |
110 |
||
14287 |
13362 |
||||
8 |
1450 |
3297 |
3620 |
Y132M-4 |
7.5 |
3957 |
3665 |
||||
4616 |
3647 |
||||
5275 |
3584 |
Y160L-4 |
15 |
||
5825 |
3507 |
||||
6484 |
3384 |
||||
7144 |
3231 |
||||
9 |
1450 |
4695 |
4597 |
Y160L-4 |
15 |
5633 |
4655 |
||||
6572 |
4632 |
||||
7511 |
4551 |
||||
8294 |
4453 |
Y180L-4 |
22 |
||
9233 |
4297 |
||||
10171 |
4101 |
||||
10 |
1450 |
6440 |
5840 |
Y200L-4 |
30 |
7942 |
5941 |
||||
9445 |
5891 |
||||
10947 |
5740 |
||||
12450 |
5495 |
||||
13952 |
5244 |
Y225S-4 |
37 |
||
15455 |
4958 |
||||
11.2 |
1450 |
9047 |
7364 |
Y225M-4 |
45 |
11158 |
7491 |
||||
13269 |
7428 |
||||
15380 |
7236 |
||||
17491 |
6927 |
Y280S-4 |
75 |
||
19602 |
6609 |
||||
21713 |
6246 |
||||
11.2 |
960 |
5990 |
3182 |
Y180L-6 |
15 |
7388 |
3237 |
||||
8785 |
3210 |
||||
10182 |
3128 |
||||
11580 |
2996 |
||||
12978 |
2860 |
Y200L2-6 |
22 |
||
14375 |
2705 |
||||
12.5 |
1450 |
12577 |
9229 |
Y280S-4 |
75 |
15512 |
9390 |
||||
18447 |
9310 |
||||
21381 |
9068 |
Y315S-4 |
110 |
||
24316 |
8678 |
||||
27251 |
8278 |
||||
30186 |
7822 |
||||
12.5 |
960 |
8327 |
3975 |
Y200L2-6 |
22 |
10270 |
4043 |
||||
12213 |
4009 |
||||
14156 |
3907 |
||||
16099 |
3741 |
Y250M-6 |
37 |
||
18042 |
3571 |
||||
19985 |
3377 |
||||
14 |
1450 |
17670 |
11668 |
Y315M-4 |
132 |
21793 |
11874 |
||||
25916 |
11771 |
||||
30040 |
11464 |
Y355M-4 |
220 |
||
34163 |
10967 |
||||
38286 |
10457 |
||||
42409 |
9878 |
||||
14 |
960 |
11699 |
5004 |
Y250M-6 |
37 |
14428 |
5090 |
||||
17158 |
5047 |
||||
19888 |
4917 |
Y315S-6 |
75 |
||
22618 |
4709 |
||||
25348 |
4494 |
||||
28078 |
4249 |
||||
16 |
1450 |
26377 |
15425 |
Y355M3-4 |
315 |
32531 |
15700 |
||||
38686 |
15563 |
||||
44841 |
15151 |
||||
50995 |
14488 |
||||
57150 |
13808 |
JS138-4 |
410 |
||
63305 |
13035 |
||||
16 |
960 |
17463 |
6570 |
Y315S-6 |
75 |
21538 |
6683 |
||||
25613 |
6627 |
||||
29687 |
6456 |
Y315L1-6 |
110 |
||
33762 |
6180 |
||||
37837 |
5898 |
||||
41912 |
5575 |
motor