9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan

Product Details
Customization: Available
Material: Iron
Usage: for Experiment, for Air Conditioner, for Manufacture, for Refrigerate
Still deciding? Get samples of US$ 1250/Set
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (15)
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
  • 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Installation Instructions
  • Company Profile
  • Certifications
  • Our Advantages
Overview

Basic Info.

Model NO.
9-19 Series Centrifugal
Flow Direction
Centrifugal
Pressure
High Pressure
Certification
RoHS, UR, ISO, CE, CCC
Color
Red/Blue/Green etc.
Protection Level
IP55/IP65
Insulation Level
F/H
Transportation Method
Sea Transportation, Land Transportation
Transport Package
Wooden Packing
Specification
Different models, different sizes
Trademark
HENGDING
Origin
China
HS Code
8414513000
Production Capacity
10, 000 Units/Year

Packaging & Delivery

Package Size
240.00cm * 130.00cm * 190.00cm
Package Gross Weight
400.000kg
Lead Time
4 days (1 - 5 Sets)
7 days (6 - 10 Sets)
10 days (11 - 30 Sets)
To be negotiated ( > 30 Sets)

Product Description

Product Description

The 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan is an industrial-grade ventilation solution specifically engineered to handle high-pressure air movement under extreme conditions. This advanced fan system is designed to operate safely and reliably in environments involving high-temperature gases, combustible dust, and explosive atmospheres. With its robust construction, exceptional efficiency, and innovative design, this fan is ideal for industries such as petrochemical, metallurgy, power generation, cement production, and more.

Built-In Features

The 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan incorporates a series of advanced components and high-quality materials to ensure exceptional performance and durability:

  1. Explosion-Proof Motor: Equipped with a high-efficiency explosion-proof motor that complies with international explosion-proof standards (ATEX, IECEx). It provides safe and reliable operation in hazardous environments with combustible gases or dust.

  2. High-Strength Casing: The fan housing is constructed from heavy-duty steel with a specialized heat-resistant coating, ensuring excellent thermal stability and corrosion resistance. The robust casing also reduces vibrations and noise during operation.

  3. High-Temperature Bearings: Designed with reinforced, lubricated, and heat-resistant bearings to withstand extreme temperatures without degradation over long operational periods.

  4. Dynamic Impeller Design: The fan features an aerodynamically optimized, precision-engineered impeller made of alloy materials. It ensures smooth airflow, minimal energy loss, and efficient gas conveyance.

  5. Heat Dissipation System: Built-in thermal management systems efficiently dissipate heat, allowing the fan to maintain optimal temperatures during continuous operation.

  6. Explosion-Proof Electrical Components: All electrical connections and controls are explosion-proof to prevent sparks and ensure compliance with safety requirements in hazardous applications.

Design and Construction

The design of the 9-19 Series Fan prioritizes safety, efficiency, and operational longevity. The fan is engineered with high-pressure and high-temperature gas conveyance in mind, ensuring reliable performance even in the most demanding industrial environments:

  1. Impeller Configuration: The dynamic impeller design includes backward-curved blades that effectively handle high pressures while maintaining smooth airflow and low energy consumption. The blades are carefully balanced for vibration-free operation.

  2. Compact Layout: The fan's compact and modular design ensures space efficiency while maintaining high operational output. Its versatile mounting options allow for installation in tight or restricted spaces.

  3. Optimized Airflow Path: The flow path of air or gas through the fan has been carefully optimized using computational fluid dynamics (CFD) simulations. This enhances efficiency and reduces energy losses during operation.

  4. Sealed Construction: The fan is fully sealed to prevent leaks, ensuring safe operation in explosive environments. The housing and connections are reinforced for additional durability.

  5. Cooling Mechanisms: Integrated cooling systems and heat-resistant components protect the fan from overheating, enhancing its lifespan and minimizing maintenance costs.

Advantages

The 9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan offers numerous advantages that set it apart in the market:

  1. Exceptional Safety: Designed for hazardous industrial environments, the fan is explosion-proof and compliant with global safety certifications, ensuring safe operation in explosive and combustible atmospheres.

  2. High Performance: With its advanced aerodynamic design and precision-engineered components, the fan delivers superior airflow efficiency, reduced energy consumption, and consistent high-pressure output.

  3. Heat Resistance: Capable of handling high-temperature gases without performance degradation, the fan is suitable for applications involving extreme heat, such as metallurgy, boilers, and drying systems.

  4. Durable and Long-Lasting: Constructed with high-strength materials and heat-resistant components, the fan is built for long-term durability under harsh industrial conditions.

  5. Energy Efficiency: The backward-curved impeller and optimized design minimize energy losses, leading to significant energy savings over time.

  6. Low Noise and Vibration: The dynamically balanced impeller and vibration-reducing design ensure quiet and smooth operation, improving the overall working environment.

  7. Easy Maintenance: The fan's modular construction allows for easy disassembly, inspection, and maintenance, reducing downtime and operational costs.

  8. Versatile Applications: The fan is suitable for a wide range of industrial applications, including gas conveyance, ventilation systems, drying systems, and material handling processes.

Applications

The 9-19 Series Fan is widely used in industrial sectors where high-pressure ventilation and safe gas conveyance are critical. Typical applications include:

  1. Petrochemical plants

  2. Metallurgical processes

  3. Power generation facilities

  4. Cement production lines

  5. Boilers and drying systems

  6. Chemical processing industries

  7. Grain and food processing plants

  8. Material handling and conveying systems

  9. Hazardous gas exhaust systems

  10. High-temperature industrial kilns

Device Configuration
Fan form: A-type motor direct connection, C-type belt drive, D-type coupling drive;
Motor brand: Yineng Motor (default), Lu'an Motor, Wannan Motor, Siemens and other well-known brands (can be specified);
Impeller: high-quality carbon steel, stainless steel, rubber lining, wear-resistant layer or wear-resistant lining plate, ceramic patch (can be specified);
Spindle: high-strength carbon steel, stainless steel, composite steel, etc.;
Bearing seat: cast iron
Optional configurations: Integral bracket; Protective cover; Muffler; Inlet and outlet compensator; Inlet and outlet matching flange; Adjusting door; Electric actuator; Shock absorber; Diaphragm coupling; Hydraulic coupler; Motor rain cover; Temperature sensor; Vibration sensor; Soft start device; Inverter;

 
Detailed Photos
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
 
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
Product Parameters
Fan model 8-09, 9-19, 9-26,10-19 etc.
Pressure 600Pa ~ 90000Pa
Air volume 1.6m³/s ~ 352m³/s
Power 1.1kW ~ 1600kW
Model Rotating Speed Air Volume Full Pressure Motor
No R/min m3/h Pa Model Power  kw
4 2900 824 3584 Y90L-2 2.2
970 3665
1116 3647
1264 3597
1410 3507 Y100L-2 3
1558 3384
1704 3253
4.5 2900 1174 4603 Y112M-2 4
1397 4684
1616 4672
1839 4580
2062 4447
2281 4297 Y132S1-2 5.5
2504 4112
5 2900 1610 5697 Y132S2-2 7.5
1932 5768
2254 5740
2576 5639
2844 5517
3166 5323
3488 5080 Y160M1-2 11
5.6 2900 2262 7182 Y160M1-2 11
2714 7273
3167 7236
3619 7109
3996 6954 Y160L-2 18.5
4448 6709
4901 6400
6.3 2900 3220 9149 Y160L-2 18.5
3865 9265
4509 9219
5153 9055
5690 8857 Y200L1-2 30
6334 8543
6978 8148
7.1 2900 4610 11717 Y200L2-2 37
5532 11868
6454 11807
7376 11596
8144 11340 Y250M-2 55
9066 10935
9988 10426
8 2900 6594 15034 Y280S-2 75
7913 15229
9232 15151
10550 14877
11649 14546
12968 14021 Y315S-2 110
14287 13362
8 1450 3297 3620 Y132M-4 7.5
3957 3665
4616 3647
5275 3584 Y160L-4 15
5825 3507
6484 3384
7144 3231
9 1450 4695 4597 Y160L-4 15
5633 4655
6572 4632
7511 4551
8294 4453 Y180L-4 22
9233 4297
10171 4101
10 1450 6440 5840 Y200L-4 30
7942 5941
9445 5891
10947 5740
12450 5495
13952 5244 Y225S-4 37
15455 4958
11.2 1450 9047 7364 Y225M-4 45
11158 7491
13269 7428
15380 7236
17491 6927 Y280S-4 75
19602 6609
21713 6246
11.2 960 5990 3182 Y180L-6 15
7388 3237
8785 3210
10182 3128
11580 2996
12978 2860 Y200L2-6 22
14375 2705
12.5 1450 12577 9229 Y280S-4 75
15512 9390
18447 9310
21381 9068 Y315S-4 110
24316 8678
27251 8278
30186 7822
12.5 960 8327 3975 Y200L2-6 22
10270 4043
12213 4009
14156 3907
16099 3741 Y250M-6 37
18042 3571
19985 3377
14 1450 17670 11668 Y315M-4 132
21793 11874
25916 11771
30040 11464 Y355M-4 220
34163 10967
38286 10457
42409 9878
14 960 11699 5004 Y250M-6 37
14428 5090
17158 5047
19888 4917 Y315S-6 75
22618 4709
25348 4494
28078 4249
16 1450 26377 15425 Y355M3-4 315
32531 15700
38686 15563
44841 15151
50995 14488
57150 13808 JS138-4 410
63305 13035
16 960 17463 6570 Y315S-6 75
21538 6683
25613 6627
29687 6456 Y315L1-6 110
33762 6180
37837 5898
41912 5575
 
Installation Instructions
1) Before installing the fan, the mechanical and electrical area must check the appearance of the fan. If it is not qualified, installation is not allowed.

2) The air inlet of the fan must be clear and unobstructed within 2 meters. No accumulation of debris or placement of starting devices is allowed. The installation location of the starting device must be convenient for personnel to operate.

3) After installation, carefully check whether the ventilator is deformed or damaged and whether the connecting bolts and base snap rings are secure.

4) The ventilator must be managed and operated by a dedicated person.
 
Company Profile
9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan
Certifications

9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan

Our Advantages

9-19 Series High Temperature Gas Conveying High Pressure Explosion-Proof Ventilation Fan



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier