Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan

Product Details
Customization: Available
Material: Iron
Usage: for Experiment, for Air Conditioner, for Manufacture, for Refrigerate
Still deciding? Get samples of US$ 400/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
In-stock Capacity
The supplier has In-stock capacity
Quality Assurance
The supplier provides quality assurance
100% Finished Products Inspection
The supplier inspects 100% of finished products.
to see all verified strength labels (15)
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
  • Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Find Similar Products
  • Overview
  • Product Description
  • Product Categories
  • Product Parameters
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
4-72/4-73/4-68
Flow Direction
Centrifugal
Pressure
High Pressure
Certification
RoHS, UR, ISO, CE, CCC
Protection Level
IP55/IP65
Insulation Level
F/H
Frequency
50Hz/60Hz
Cooling Type
Air Cooling/Circulating Water Cooling
Warranty
10 Years
Temperature Resistance
High Temperature Proof (up to 800 °c)
Transport Package
Wooden Packing
Specification
Different models, different sizes
Trademark
HENGDING
Origin
China
HS Code
8414513000
Production Capacity
10, 000 Units/Year

Packaging & Delivery

Package Size
320.00cm * 190.00cm * 240.00cm
Package Gross Weight
340.000kg
Lead Time
7 days (1 - 10 Pieces)
To be negotiated ( > 10 Pieces)

Product Description

Product Description

Product Overview Our Centrifugal Induced Draft Fan is specifically designed to meet the demands of large-scale industrial boilers, ensuring efficient air supply and optimal combustion. Engineered to deliver large air volumes, this high-performance blower is ideal for a variety of boiler systems, including steam boilers, thermal oil boilers, and other industrial heating applications.

Key Features

  • Large Air Volume: Designed to handle high air flow requirements, ensuring sufficient oxygen supply for enhanced boiler combustion efficiency.

  • High Efficiency: Optimized impeller design and advanced aerodynamic features reduce energy consumption while maximizing airflow.

  • Durable Construction: Made with high-strength materials to withstand high temperatures, corrosive environments, and prolonged industrial operation.

  • Low Noise Operation: Equipped with noise-reducing features, ensuring smooth and quiet operation.

  • Customizable Design: Available in various sizes and configurations to meet specific performance requirements of your boiler system.

Applications

  • Industrial Boilers

  • Power Plant Boilers

  • Heating Systems

  • Thermal Oil Boilers

  • Combustion Air Supply Systems

Performance Advantages

  1. Enhanced Boiler Efficiency: Provides consistent and powerful air supply to support complete fuel combustion, reducing fuel wastage and emissions.

  2. Cost-Effective: Energy-efficient operation helps lower energy consumption, reducing operational costs over time.

  3. Reliable Performance: Built to operate under extreme industrial conditions, offering long-lasting and reliable service.

Technical Specifications

  • Airflow Capacity: Up to [specific air volume value, e.g., 50,000 m³/h]

  • Pressure Range: [Pressure range, e.g., 500-3000 Pa]

  • Material: High-strength carbon steel / stainless steel options

  • Motor Power: [Power range, e.g., 5.5-250 kW]

  • Speed: Adjustable speed options to suit varying airflow demands

Why Choose Us? At Zibo Hengding Fan Co., Ltd., we specialize in high-performance industrial fans tailored to your operational needs. With decades of experience and a commitment to quality, we deliver reliable, efficient, and durable solutions that drive your business forward.

For more details or to request a customized solution, contact us today!

 
Product Categories
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Boiler Blower

Medium: air
Temperature: 20ºC
Air volume: 3000m³/h~200000m³/h
Full pressure: 1000Pa~30000Pa
Power: 3kW~1000kW
Introduction: The boiler blower can transport gas with high pressure and large air volume, which can improve the combustion efficiency of the boiler.
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Boiler induced draft fan (ID Fan)

Medium: Flue gas
Temperature: 120ºC~300ºC
Air volume: 3000m³/h~600000m³/h
Full pressure: 1000Pa~23000Pa
Power: 30kW~2500kW
Introduction: In boiler systems or combustion systems, it is often necessary to use an induced draft fan to create negative air pressure to extract the gas in the system. Whether it is high temperature gas or dirty air, our company has various types of fans that can be used as induced draft fans and can withstand harsh working environments.
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Boiler primary fan (PA Fan)

Medium: air
Temperature: 20ºC
Air volume: 3000m³/h~200000m³/h
Full pressure: 1000Pa~23000Pa
Power: 30kW~1000kW
Introduction: The primary air fan is matched with the air supply fan on the pulverized coal furnace and circulating fluidized bed boiler, and is used to transport pulverized coal. Its function is to provide a certain pressure and a certain flow of primary air to dry the pulverized coal and send it to the burner. Provides the heat required for the combustion of volatile pulverized coal. At the same time, it can also coordinate with the secondary air to provide combustion support for pulverized coal combustion. The flow rate of the primary fan mainly depends on the primary air volume required by the combustion system and the air leakage volume of the air preheater.
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Boiler secondary air fan (SA Fan)

Medium: air
Temperature: 20ºC
Air volume: 3000m³/h~200000m³/h
Full pressure: 1000Pa~23000Pa
Power: 30kW~1000kW
Introduction: The boiler secondary air fan can provide an appropriate amount of auxiliary air to make the fuel burn more fully and efficiently, thereby improving thermal efficiency and reducing energy consumption.
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Flue gas desulfurization fan (FGD Fan)

Medium: air
Temperature: 400ºC
Air volume: 3000m³/h~120000m³/h
Full pressure: 1000Pa~23000Pa
Power: 30kW~1000kW
Introduction: Flue gas desulfurization fan (FGD Fan) is a forced ventilation system when the desulfurization and denitrification systems are working. It has the characteristics of compact structure, high operating efficiency and high pressure. It is a good match for the gas sealing of the current desulfurization and denitrification systems. effect.
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
Pulverized coal fan

Medium: pulverized coal air
Temperature: 100ºC
Air volume: 3000m³/h~120000m³/h
Full pressure: 1000Pa~23000Pa
Power: 30kW~1000kW
 
Product Parameters
Machine Number Rotating Speed r/min Flow m3/h Full Pressure Pa Full Pressure % Full Pressure KW Required power KW Electric motor
Model Power kw
3.2A 2900 1688 1300 69.3 0.88 1.23 Y90L-2 (B35) 2.2
1955 1263 73.2 0.93 1.31
2209 1220 75.5 0.99 1.38
2476 1160 76.8 1.03 1.34
2729 1091 76.9 1.07 1.39
2996 1006 75.6 1.1 1.43
3250 918 73.2 1.13 1.47
3517 792 69.3 1.11 1.45
4A 2900 4012 2014 77 2.89 3.47 Y132S1-2 (B35) 5.5
4506 1969 80.3 3.05 3.66
4973 1915 82.5 3.18 3.82
5468 1830 84.1 3.28 3.94
5962 1723 84.6 3.35 4.02
6457 1606 83.7 3.42 4.11
6924 1459 81.4 3.43 4.11
7419 1320 77.5 3.49 4.19
4.5A 2900 5712 2554 77 5.21 6 Y132S2-2(B35) 7.5
6416 2497 80.3 5.49 6.32
7081 2428 82.5 5.74 6.6
7785 2320 84.1 5.92 6.81
8489 2184 84.6 6.04 6.95
9194 2036 83.7 6.17 7.09
9859 1849 81.4 6.17 7.1
10562 1673 77.5 6.3 7.24
5A 2900 7728 3187 77.6 8.72 10.02 Y160M2-2(B35) 15
8855 3145 81.8 9.35 10.76
9928 3074 84.7 9.9 11.39
11054 2962 86 10.47 12.04
12128 2792 86.1 10.82 12.44
13255 2567 84.6 11.07 12.72
14328 2335 82.1 11.22 12.9
15455 2019 77.6 11.09 12.75
6A 1450 6677 1139 77.6 2.71 3.25 Y112M-4 (B35) 4
7650 1124 81.8 2.91 3.49
8578 1099 84.7 3.08 3.7
9551 1059 86 3.26 3.91
10478 999 86.1 3.36 4.04
11452 919 84.6 3.44 4.13
12379 836 82.1 3.49 4.19
13353 724 77.6 3.45 4.14
6D 1450 6677 1139 77.6 2.71 3.32 Y112M-4 4
7650 1124 81.8 2.91 3.56
8578 1099 84.7 3.08 3.77
9551 1059 86 3.26 3.99
10478 999 86.1 3.36 4.12
11452 919 84.6 3.44 4.21
12379 836 82.1 3.49 4.27
13353 724 77.6 3.45 4.22
8D 1450 15826 2032 77.6 11.42 13.41 Y180M-4 18.5
18134 2005 81.8 12.26 14.39
20332 1960 84.7 12.98 15.23
22640 1888 86 13.72 16.1
24838 1781 86.1 14.18 16.64
27146 1638 84.6 14.5 17.02
29344 1490 82.1 14.71 17.26
10D 1450 40441 3202 86.7 41 48.12 Y250M-4 55
44026 3159 88.7 43.07 50.53
47611 3032 89 44.59 52.33
50680 2884 86.1 1.81 2.4
53664 2722 84.6 1.85 2.45
56605 2532 82.1 1.88 2.49
12D 960 46267 2013 86.7 29.61 34.75 Y280S-6 45
50368 1986 88.7 31.1 36.49
54469 1906 89 32.2 37.79
57981 1814 88.2 32.91 38.62
61395 1712 86.6 33.51 39.32
64759 1593 84.2 33.84 39.71
6C 2240 10314 2734 77.3 10 12.1 Y160L-4 15
11818 2698 81.8 10.73 12.98
13251 2637 84.7 11.35 13.74
14755 2541 86 12 14.53
16187 2396 86.1 12.41 15.02
17692 2202 84.6 12.69 15.36
19124 2004 82.1 12.87 15.57
20628 1733 77.6 12.71 15.39
6C 2000 9209 2176 77.6 7.11 8.61 Y160M-4 11
10552 2147 81.8 7.64 9.24
11831 2099 84.7 8.08 9.78
13174 2022 86 8.54 10.34
14453 1907 86.1 8.83 10.69
15796 1753 84.6 9.03 10.63
17075 1595 82.1 9.16 11.09
18418 1380 77.6 9.05 0.95
8C 1800 19646 3143 77.6 21.85 26.45 Y200L1-2 30
22511 3101 81.8 23.46 28.39
25240 3032 84.7 24.83 30.05
28105 2920 86 26.25 31.77 Y200L2-2 37
30834 2754 86.1 27.12 32.83
33699 2531 84.6 27.74 33.58
36427 2302 82.1 28.13 34.05
8C 1600 17463 2478 77.6 15.35 18.58 Y180M-2 22
20010 2445 81.8 16.47 19.94
22435 2390 84.7 17.44 21.1
24982 2303 86 18.43 22.31 Y200L1-2 30
27408 2171 86.1 19.05 23.06
29954 1996 84.6 19.49 23.59
32380 1816 82.1 19.76 23.92
10C 1250 34863 2373 86.7 26.27 31.8 Y225S-4 37
37953 2341 88.7 27.59 33.4
41044 2247 89 28.57 34.58
43690 2138 88.2 29.2 35.35
46262 2018 86.6 29.73 35.99
48797 1877 84.2 30.02 36.34
10C 1120 31237 1902 86.7 18.9 22.87 Y200L-4 30
34006 1877 88.7 19.85 24.02
36775 1801 89 20.55 24.87
39146 1714 88.2 21 25.43
41451 1618 86.6 21.38 25.89
43722 1505 84.2 21.59 26.14
12C 1120 53978 2746 86.7 47.02 56.92 Y280S-4 75
58763 2710 88.7 49.38 59.78
63548 2601 89 51.13 61.9
67645 2474 88.2 52.27 63.27
71627 2335 86.6 53.21 64.41
75552 2172 84.2 53.73 65.04
12C 1000 48195 2185 86.7 33.47 40.51 Y225M-4 45
52467 2156 88.7 35.15 42.55
56739 2070 89 36.4 44.06
60397 1969 88.2 37.2 45.03
63953 1859 86.6 37.88 45.85 Y225M-4 55
67457 1729 84.2 38.25 49.3


 
Packaging & Shipping

Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
 

Installation Instructions
Option 1: Our company can provide remote video guidance for installation through WhatsApp, Wechat and other chat software.

Option 2: Our company sends employees with more than 15 years of service to the site to guide installation.

 
Company Profile
Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion FanCentrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan
 
Certifications

Centrifugal Induced Draft Fan Large Air Volume Boiler Blower Boiler Combustion Fan

FAQ
Q. What information should I provide when inquiring?
A: Fan name/model, KW, Air pressure, Flow rate Air Volume, and temperature

Q. What is your warranty?
A. Our warranty is 18 months after receiving the fans. During the warranty period, replace the damaged parts free of charge. Out warranty period, to provide timely, high-quality technical services and price concessions for spare parts to ensure.
continuous safe and high-quality equipment operation.

Q. How does your factory control product quality?
A. We have a quality inspection department. All fans are running more than 3 hours before delivery to test the quality. If there is a quality problem, we will produce a new one.

Q. What are your terms of payment?
A. TT 40% AS THE ADVANCE PAYMENT AND TT 60% AFTER INSPECTION BEFORE SHIPPING.
B. 100% IRREVOCABLE L/C AT STGHT.

Q. What products do you produce?
A. Centrifugal fan, tunnel fan, axial fan, jet fan, mining fan, exhaust fan, anti-corrosion blower, high-pressure blower, explosion-proof fan, fan accessories, etc. Please contact us to learn more details.

Q. Where is your factory? Can I visit your factory?
A. Zibo Hengding Fan Co., Ltd. is located in Industrial Park, Beijiao Town, Zhoucun District, Zibo City, Shandong Province, China.

Q. How long will it take to ship after the order?
A. 10-15 days if you need it urgently, we can discuss it for a short time.

Q. Is the product customizable?
A. Various types can be customized.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier